Xerox DocuColor 2240 Service Manual page 1119

Hide thumbs Also See for DocuColor 2240:
Table of Contents

Advertisement

Chain-Link
Name
742-094
Pre-T/A Start Timing 3TM-Tray 3
DC3535
742-095
Pre-T/A Start Timing 3TM-Tray 4
DC2240/1632
742-095
Pre-T/A Start Timing 3TM-Tray 4
DC3535
742-096
Pre-T/A Start Timing TTM-Tray 3
DC2240/1632
742-096
Pre-T/A Start Timing TTM-Tray 3
DC3535
742-097
Pre-T/A Start Timing TTM-Tray 4
DC2240/1632
742-097
Pre-T/A Start Timing TTM-Tray 4
DC3535
742-098
Main Feed Start Timing 3TM-Tray 2
DC2240/1632
742-098
Main Feed Start Timing 3TM-Tray 2
DC3535
742-099
Main Feed Start Timing 3TM-Tray 3
DC2240/1632
742-099
Main Feed Start Timing 3TM-Tray 3
DC3535
742-100
Main Feed Start Timing 3TM-Tray 4
DC2240/1632
742-100
Main Feed Start Timing 3TM-Tray 4
DC3535
742-101
Main Feed Start Timing TTM-Tray 3
DC2240/1632
742-101
Main Feed Start Timing TTM-Tray 3
DC3535
742-102
Main Feed Start Timing TTM-Tray 4
DC2240/1632
742-102
Main Feed Start Timing TTM-Tray 4
DC3535
742-103
Select Metric or Inch (Tray 5 Auto
Detect)
742-104
Select 2ndBTR Cleaning (Tray 5 Auto
Detect)
742-105
RegiLoop Length Adjust (DUP)
742-106
Pre-T/A Start Timing 3TM-Tray 2 (Half) 37
742-107
Pre-T/A Start Timing 3TM-Tray 3 (Half) 37
742-108
Pre-T/A Start Timing 3TM-Tray 4 (Half) 37
742-109
Pre-T/A Start Timing TTM-Tray 3 (Half) 37
General Procedures and Information
742--xxx Paper Handling NVM List
Table 1 Chain 742
Default
Range
Description
118
0~183
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (365~865 msec.) (1bit=1.5418 msec.)
139
0~215
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (429~929 msec.) (1bit=1.31136 msec.)
118
0~183
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (429~929 msec.) (1bit=1.5418 msec.)
139
0~215
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (457~957 msec.) (1bit=1.31136 msec.)
118
0~183
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (457~957 msec.) (1bit=1.5418 msec.)
139
0~215
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (431~931 msec.) (1bit=1.31136 msec.)
118
0~183
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (431~931 msec.) (1bit=1.5418 msec.)
38
0~83
Sets time between Main Feed Start and Pre-T/A (330~830 msec.). (1bit=1.31136 msec.)
32
0~71
Sets time between Main Feed Start and Pre-T/A (330~830 msec.). (1bit=1.5418 msec.)
38
0~83
Sets time between Main Feed Start and Pre-T/A (570~1070 msec.). (1bit=1.31136 msec.)
32
0~71
Sets time between Main Feed Start and Pre-T/A (570~1070 msec.). (1bit=1.5418 msec.)
38
0~83
Sets time between Main Feed Start and Pre-T/A (810~1310 msec.). (1bit=1.31136 msec.)
32
0~71
Sets time between Main Feed Start and Pre-T/A (810~1310 msec.). (1bit=1.5418 msec.)
38
0~83
Sets time between Main Feed Start and Pre-T/A (780~1280 msec.). (1bit=1.31136 msec.)
32
0~71
Sets time between Main Feed Start and Pre-T/A (780~1280 msec.). (1bit=1.5418 msec.)
38
0~83
Sets time between Main Feed Start and Pre-T/A (1410~1910 msec.). (1bit=1.31136 msec.)
32
0~71
Sets time between Main Feed Start and Pre-T/A (1410~1910 msec.). (1bit=1.5418 msec.)
XC=1;
0~1
0=metric (A/B) paper; 1=Inch-sized paper
XE=00
1
0~1
0=No; 1=Yes
35
0~79
Lead Regi Length Adjustment (P Speed) from Dup (Feeding Length Letter-LEF and longer)Default=157ms
(1bit=2.4462 msec.)
0~58
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (303~803 msec.) (1bit=4.8924 msec.)
0~58
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (365~865 msec.) (1bit=4.8924 msec.)
0~58
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (429~929 msec.) (1bit=4.8924 msec.)
0~58
Adjusts the Time between Pre-T/A Starts and Standard Signal (IOT) (457~957 msec.) (1bit=4.8924 msec.)
09/03
6-28
Initial issue
DC 3535/2240/1632, WC M24