DC Quick (CODE Number LIST)

Once in the Service Mode, dC Routines can be selected by dC Number or by selecting the
appropriate tabs starting at the Service Entry Screen.
Procedure
1.
Enter the Diagnostic Mode. Refer to
2.
Using the DC Quick pull-down menu (upper-right side of Diagnostics Service Entry
Screen), select the desired dC routine.
Table 1
is a complete list of dC Routines that are available from the DC Quick pull-down
menu.
Table 1 dC Routines
dC Number
Name
100
Service Entry Screen
118
Jam Counter
120
Fault Counters
122
Shut-down History
129
Automatic Setting: Adjust Sys-
tem Registration
131
NVM access: Read/Write
NVM
Initial issue
DC 3535/2240/1632, WC M24
Entering Diagnostic Mode using the
PWS.
Description
1.
Displays the Service Routine Tabs.
2.
Lists Active Faults
3.
Lists the item names of the HFSIs
that exceeded life expectancy.
4.
Lists the jams that have occurred
since the last Call Closeout.
5.
Displays IOT S/W Version.
6.
Lists the total copies/prints
Displays the following: Number of jam
events since the last Complete Closeout
(performed in Service Exit) to the current
Number of jams.
Displays the following: Number of Fault
events after the last Complete Closeout
(performed in Service Exit) to the current
copy count.
1.
Displays the history in three catego-
ries: Document Jam, Paper Jam and
Other Fault.
2.
Displays the most recent 40 Faults
(without categorizing)
The IOT lead registration and side regis-
tration are matched.
You can reference or set/change the NVM
data.
dC Number
Name
132
Set Machine Serial Number.
Read Billing Meter Information
135
Service Data
HFSI Counter
140
Component Check: Analog
Monitor
188
Service Mode Exit Screen
301
NVM access: NVM initializa-
tion
305
System Test: Component
Operation Check UI Compo-
nent Check
330
Component Check: Compo-
nent Control
351
NVM Background Processing 1.
355
HDD Diagnostics
09/03
6-5
Table 1 dC Routines
Description
If you have replaced the PWB that has a
Machine Serial Number, check the PWB
and set the Machine Serial Number.
Reads Billing Meter Information for the fol-
lowing:
MCU PWB
ESS PWB
ESS NVM PWB
Displays the regular part replacement life
expectancy (threshold) and current value
(usage). You can change the replacement
life expectancy to a preset value in the
PWS database and reset the current
value.
Monitor the analog values of the sensors
(A/D conversion) while operating the com-
ponents (e.g., C.C). You can temporarily
change the output value.
Displays the requirements for exit from the
Service Mode.
Initiates NVM Data initialization
Checks the UI Screen and Component
Panel Button operation.
Displays the instructions and results of the
Input Component Check and Output Com-
ponent Check
1.
You can monitor each Input Compo-
nent or check the operation of each
Output Component.
2.
You can simultaneously check multi-
ple Input Components and Output
Components up to 11 total.
Saves and restores values of all
NVM in PWS dC131 database.
NOTE: Background Read must com-
plete prior to saving.
2.
Start and Stop background NVM
Read.
3.
Saves/restores machine settings.
Saves NVM values listed:
4.
Resets all HFSI.
5.
Batch write of region-specific NVM.
Perform maintenance on HDD.
General Procedures and Information
DC Quick

Advertisement