116-742 Logo registry error
The logo data cannot be registered because of the restriction of the number of logos.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to service call procedures.
Use the Operation Panel utility to check the registered logos, and delete unnecessary ones. Or
delete unnecessary logos with the Print command.
Initial issue
DC 3535/2240/1632, WC M24
116-743 Form/logo size overflow
The received data (forms/logos) indicating that forms/logos cannot be registered (due to insuf-
ficient area) exceeded the registered buffer size.
Procedure
Switch power off then on. The problem continues.
Y
N
Return to service call procedures.
Increase the form registry area size from the Operation Panel. Or install the HD.
09/03
2-683
Status Indicator RAPs
116-742, 116-743