3. Remove the vent plugs; then (if necessary) fill
the battery with distilled water to the upper
level indicated on the battery.
4. Trickle charge the battery at 1.4 amps for 10
hours.
! CAUTION
Never exceed the standard charging rate.
5. After charging, check fluid level and fill with
distilled water as necessary; then install vent
plugs.
! CAUTION
Before installing the battery, make sure the ignition
switch is in the OFF position.
6. Place the battery into position in the ATV and
secure with the hold-down bracket.
7. Attach the vent tube and check the vent tube to
make sure it is not crimped or obstructed in any
way and that it is properly routed through and
secured to the frame.
8. Connect cables to the proper terminals: positive
cable to the positive terminal (+) and negative
cable to the negative terminal (-). Connect the
negative cable last.
! CAUTION
Connecting cables in reverse (positive to negative
and negative to positive) can cause serious dam-
age to the electrical system.
Back
2-4
AF733D
Back to TOC

FUSES

The fuses are located in a power distribution module
under the seat.
If there is any type of electrical system failure,
always check the fuses first.
NOTE: To remove the fuse, compress the locking
tabs on either side of the fuse case and lift out.
400/500/500 TBX/FIS Auto
400 FIS Manual/500 Manual
650 V-Twin
TRV/VP/400 TBX
Back to Section TOC
0411-828
0411-837
0411-903
0411-838
Next