17. Remove the clamp securing the upper coolant
hose to the thermostat housing; then disconnect
the hose.
18. Disconnect the high tension lead from the spark
plug; then remove the coil.
19. Disconnect the battery ground (negative) cable
from the crankcase cover; then disconnect the
positive cable from the starter motor.
Back
3-194
CD787
CD786
CC335D
Back to TOC
20. Remove the clamp securing the lower coolant
hose to the water pump housing; then disconnect
the hose.
21. Loosen the clamp on the crankcase breather vent
hose; then remove the hose.
Back to Section TOC
AR600D
AR604D
CC334D