Fuses; Air Cleaner - Arctic Cat DVX 400 2008 Service Manual

Table of Contents

Advertisement

FOR ARCTIC CAT ATV DISCOUNT PARTS CALL 606-678-9623 OR 606-561-4983
NOTE: If voltage in step 7 is below specifica-
tions, charge the battery an additional 1-5 hours;
then retest.
8. Place the battery in the battery compartment; then
coat the battery posts and cable ends with a light
coat of multi-purpose grease.
! CAUTION
Before installing the battery, make sure the ignition
switch is in the OFF position.
9. Connect the battery cables (positive cable first);
then install the battery hold-down.
! CAUTION
Connecting cables in reverse (positive to negative
and negative to positive) can cause serious damage
to the electrical system.
There is one 20 amp fuse and one spare 20 amp fuse
located adjacent to the battery on the starter relay.
If there is any type of electrical system failure, always
check the fuse first.
! CAUTION
Always replace a blown fuse with a fuse of the same
type and rating.
www.mymowerparts.com
Back
2-4

Fuses

Back to TOC

Air Cleaner

CLEANING AND INSPECTING
FILTER
Failure to inspect the air filter frequently if the ATV is
used in dusty, wet, or muddy conditions can damage
the ATV engine.
1. Remove the seat.
2. Unseat the two retaining clips securing the air
cleaner housing cover; then remove the cover.
3. Remove the screw securing the air filter stopper
and set aside; then remove the filter assembly.
SP032A
4. Remove the foam wrap from the filter frame.
Back to Section TOC
! CAUTION
SP014A
SP012
Next