Magneto Coils (650 V-Twin) - Arctic Cat 400 Service Manual

Hide thumbs Also See for 400:
Table of Contents

Advertisement

NOTE: The battery must be at full charge for
these tests.
Magneto Coil (Trigger)
1. Set the meter selector to the DC Voltage posi-
tion.
2. Connect the red tester lead to the green wire;
then connect the black tester lead to the blue
wire.
3. Crank the engine over using the electric starter.
4. The meter reading must be within specification.
Magneto Coil (Source)
1. Set the meter selector to the DC Voltage posi-
tion.
2. Connect the red tester lead to the yellow wire;
then connect the black tester lead to the white
wire.
3. Crank the engine over using the electric starter.
4. The meter reading must be within specification.
PEAK VOLTAGE (500/650 H1)
NOTE: All of the peak voltage tests should be
made using the Fluke Model 73 Multimeter (p/n
0644-191) with Peak Voltage Reading Adapter (p/n
0644-307). If any other type of tester is used, read-
ings may vary due to internal circuitry.
NOTE: The battery must be at full charge for
these tests.
Magneto Coil (Trigger)
1. Set the meter selector to the DC Voltage posi-
tion.
2. Connect the red tester lead to the green wire;
then connect the black tester lead to the blue
wire.
3. Crank the engine over using the electric starter.
4. The meter reading must be within specification.
Magneto Coil (Source)
1. Set the meter selector to the DC Voltage posi-
tion.
2. Connect the red tester lead to the yellow wire;
then connect the black tester lead to the white
wire.
Back
5-16
Back to TOC
3. Crank the engine over using the electric starter.
4. The meter reading must be within specification.
Magneto Coils
(650 V-Twin)
VOLTAGE
(Regulator/Rectifier - Output)
1. Set the meter selector to the DC Voltage posi-
tion.
2. Connect the red tester lead to the positive bat-
tery post; then connect the black tester lead to
the negative battery post.
3. With the engine running at a constant 5000 RPM
(with the headlights on), the meter must show
14-15 DC volts.
! CAUTION
Do not run the engine at high RPM for more than 10
seconds.
NOTE: If voltage is lower than specified, test sta-
tor coil - no load.
VOLTAGE
(Stator Coil - No Load)
The connector is the white one on the right side
behind the engine.
NOTE: Test the connector that comes from the
engine.
1. Set the meter selector to the A.C. Voltage posi-
tion.
2. Test between the three black wires for a total of
three tests.
Back to Section TOC
KX387
Next

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

400 tbx400 trv

Table of Contents