Check Points Of Every 1 Year - Kubota GR1600EU Workshop Manual

Table of Contents

Advertisement

GR1600EU, WSM

[9] CHECK POINTS OF EVERY 1 YEAR

Replacing Air Cleaner Element
1. Change the element once a year.
Flushing Cooling System and Changing Coolant
CAUTION
To avoid personal injury:
• Do not remove the radiator cap when the engine is hot.
Then loosen cap slightly to the stop to relieve any excess
pressure before removing cap completely.
1. Stop the engine and let cool down.
2. To drain the coolant, remove the radiator drain plug (1) and
engine drain plug (2) and the hose, and remove the radiator
cap. The radiator cap must be removed to completely drain the
coolant.
3. After all coolant is drained, install the hose with the clamp.
4. Fill with clean water and cooling system cleaner.
5. Follow directions of the cleaner instruction.
6. After flushing, fill with clean water and anti-freeze until the
coolant level is just below the fill port on the radiator. Install the
radiator cap securely.
7. Fill with coolant up to "FULL" mark on the recovery tank.
8. Start and operate the engine for a few minutes.
9. Stop the engine and let cool. Check coolant level of recovery
tank (3) and add coolant if necessary.
IMPORTANT
• Do not start engine without coolant.
• Use clean, fresh water and anti-freeze to fill the radiator and
recovery tank.
• When the anti-freeze is mixed with water, the anti-freeze
mixing ratio must be less than 50 %.
• Securely tighten radiator cap. If the cap is loose or
improperly fitted, water may leak out and the engine could
overheat.
• Refer to "4. LUBRICANTS, FUEL AND COOLANT" on page
G-9.
Coolant
Capacity
(with recovery tank)
(1) Radiator Drain Plug
(2) Engine Drain Plug
(3) Recovery Tank
G-41
GENERAL
9Y1210595GEG0035US0
2.35 L
2.48 U.S.qts
2.07 Imp.qts
a:
FULL
b:
LOW
(To be continued)
KiSC issued 11, 2013 A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gr1600fGr1600id

Table of Contents