Checking Battery Condition
DANGER
To avoid the possibility of battery explosion:
For the refillable type battery, follow the instructions below.
• Do not use or charge the refillable type battery if the fluid
level is below the LOWER (lower limit level) mark.
Otherwise, the battery component parts may prematurely
deteriorate, which may shorten the battery's service life or
cause an explosion. Check the fluid level regularly and add
distilled water as required so that the fluid level is between
the UPPER and LOWER levels.
DANGER
To avoid personal injury or death:
• When the battery is being activated, hydrogen and oxygen
gases in the battery are extremely explosive. Keep open
sparks and flames away from the battery at all times,
especially when charging the battery.
WARNING
To avoid personal injury:
• Batteries, battery posts, terminals and related accessories
contain lead and lead compounds, and other chemicals
known to the State of California to cause cancer and birth
defects or other reproductive harm, WASH HANDS AFTER
HANDLING.
• Never remove the vent plugs while the engine is running.
• Keep electrolyte away from eyes, hands and clothes. If you
are spattered with it, wash it away completely with water
immediately and get medical attention.
• Wear eye protection and rubber gloves when working
around battery.
1. Mishandling the battery shortens the service life and adds to
maintenance costs.
2. The original battery is maintenance free type battery, but need
some servicing.
3. If the battery is weak, the engine is difficult to start and the lights
become dim. It is important to check the battery periodically.
• When exchanging an old battery for new one, use battery of
equal specification in table below.
Battery
Reserve
Volts (V)
Type
Capacity (min)
51R
12
(1) Battery
G-29
Cold
Cranking
Amps
80
430