Starter - Kubota GR1600EU Workshop Manual

Table of Contents

Advertisement

GR1600EU, WSM

(3) Starter

Motor Test
CAUTION
• Secure the starter to prevent it from jumping up and down
while testing the motor.
1. Disconnect the battery negative cable from the battery.
2. Disconnect the battery positive cable and the leads from the
starter.
3. Remove the starter from the engine.
4. Disconnect the connecting lead (2) from the starter C terminal
(1).
5. Connect a jumper lead from the connecting lead (2) to the
battery positive terminal post.
6. Connect a jumper lead momentarily between the starter motor
housing and the battery negative terminal post.
7. If the motor does not run, check the motor.
(1) C Terminal
Starter Magnet Switch Test (Pull-in, Holding Coils)
NOTE
• Prepare a 6 V battery for the test, and you must do each test
for 3 to 5 seconds.
1) Checking Pull-in Coil
1. Connect jumper lead from the battery's negative terminal post
to the C terminal.
2. The plunger should be attracted strongly when a jumper lead is
connected from the battery positive terminal to the S terminal.
2) Checking Holding Coil
1. Connect jumper leads from the battery's negative terminal post
to the body and the battery's positive terminal post to the S
terminal.
2. Push the plunger in by hand and release it. Then, the plunger
should remain being attracted.
6-S10
ELECTRICAL SYSTEM
(2) Connecting Lead
9Y1210595ELS0014US0
9Y1210595ELS0047US0
KiSC issued 11, 2013 A