OC60-E2, OC95-E2, WSM
[7] CHECK POINT OF EVERY 1 YEAR
[8] CHECK POINT OF EVERY 2 YEARS
Nozzle Spraying Condition
1. Check the nozzle spray condition.
2. If the spray pattern and spraying direction are faulty, replace
the nozzle piece.
(a) Good
Cleaning and Changing Air Cleaner Element
Change air cleaner element (1) once a year or six times of
cleaning.
(Cleaning Air Filter Element)
When dry dust adheres
1. To clean the element, use clean dry compressed air on the
inside of the element.
Air pressure at the nozzle must not exceed 205 kPa (2.1
, 30 psi).
Maintain reasonable distance between the nozzle and the
filter.
(1) Element
Checking Fuel Hose and Clamp Bands
1. If the clamps (1) are loose, replace with new ones.
2. The fuel and lubricating hoses are made of rubber and ages
regardless of period of service.
together with the clamps every two year.
3. However, if the fuel and lubricating hose and clamp are found
to be damaged or deteriorated earlier than two years, replace
with new ones.
(1) Clamp
G-10
GENERAL
(b) Bad
0000009212E
0000009368E
Change the fuel pipes
0000009344E