Kubota GR1600EU Workshop Manual page 239

Table of Contents

Advertisement

GR1600EU, WSM
Main Switch Continuity
1) Main Switch Key at OFF Position
1. Set the main switch OFF position.
2. Measure the resistance with an ohmmeter across the B terminal
and the ACC terminal, B terminal and ST terminal, B terminal
and G terminal.
3. If infinity is not indicated, the contacts of the main switch are
faulty.
B terminal – ACC terminal
Resistance
B terminal – ST terminal
B terminal – G terminal
2) Main Switch Key at ON Position
1. Set the main switch ON position.
2. Measure the resistance with an ohmmeter across the B terminal
and the ACC terminal.
3. If 0 ohm is not indicated, the B – ACC contact of the main switch
are faulty.
Resistance
B terminal – ACC terminal
3) Main Switch Key at PREHEAT Position
1. Set and hold the main switch key at the PREHEAT position.
2. Measure the resistance with an ohmmeter across the B terminal
and the G terminal, and measure the resistance across the B
terminal and the ACC terminal.
3. If 0 ohm is not indicated, these contacts of the main switch are
faulty.
B terminal – G terminal
Resistance
B terminal – ACC terminal
4) Main Switch Key at START Position
1. Set and hold the main switch key at the START position.
2. Measure the resistance with an ohmmeter across the B terminal
and the G terminal, across the B terminal and the ST terminal,
and across the B terminal and the ACC terminal.
3. If 0 ohm is not indicated, these contacts of the main switch are
faulty.
B terminal – G terminal
Resistance
B terminal – ST terminal
B terminal – ACC terminal
(1) G Terminal
(2) ACC Terminal
6-S9
ELECTRICAL SYSTEM
Infinity
0 Ω
0 Ω
0 Ω
(3) ST Terminal
(4) B Terminal
9Y1210595ELS0013US0
KiSC issued 11, 2013 A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gr1600fGr1600id

Table of Contents