Cheking, Disassembling And Servicing; Checking And Adjusting; Battery - Kubota GR1600EU Workshop Manual

Table of Contents

Advertisement

GR1600EU, WSM

4. CHEKING, DISASSEMBLING AND SERVICING

[1] CHECKING AND ADJUSTING

(1) Battery

Battery Voltage
1. Stop the engine and turn the main switch off.
2. Connect the COM (-) lead of the voltmeter to the battery's
negative cable (1) and the (+) lead to the positive cable (2), and
measure the battery voltage.
3. If the battery voltage is less than the factory specification, check
the battery specific gravity and recharge the battery.
Battery Voltage
Factory specification
(1) Negative Cable
(2) Positive Cable
Battery Terminal Connection
1. Turn the main switch on, and turn on the head light.
2. Measure the voltage with a voltmeter across the battery's
positive terminal post and the cable terminal, and the voltage
across the battery's negative terminal post and the chassis.
3. If the measurement exceeds the factory specification, clean the
battery terminal posts and cable clamps, and tighten them
firmly.
Potential difference
Factory specification
6-S6
ELECTRICAL SYSTEM
More than 12 V
(3) Battery
9Y1210595ELS0009US0
Less than 0.1 V
9Y1210595ELS0010US0
KiSC issued 11, 2013 A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gr1600fGr1600id

Table of Contents