GR1600EU, WSM
(13) Grass Container Full Switch [GR1600EU, GR1600F]
Grass Container Full Switch Continuity
1. Remove the battery.
2. Dismount the grass container.
3. Remove the filter cover.
4. Disconnect the connector (1) from the grass container full
switch (2).
5. Measure the resistance with an ohmmeter between the grass
container full switch terminals.
6. If the grass container full switch is damaged, replace it.
When the diaphragm of
Resistance
switch is pushed
(between switch
When the diaphragm of
terminals)
switch is released
(1) Connector
(2) Grass Container Full Switch
Buzzer
1. Remove the air intake net under the meter panel.
2. Disconnect the lead from buzzer (1).
3. Connect the jumper lead between the battery positive terminal
and terminal 1 of connector.
4. Connect the jumper lead between the battery negative terminal
and terminal 2 of connector.
5. If the buzzer does not whistle, replace it.
(1) Buzzer
6-S19
ELECTRICAL SYSTEM
0 Ω
Infinity
(3) Flap
9Y1210595ELS0035US0
1:
Terminal 1
2:
Terminal 2
9Y1210595ELS0036US0
KiSC issued 11, 2013 A