Operator Presence Control (Opc) Switch - Kubota GR1600EU Workshop Manual

Table of Contents

Advertisement

GR1600EU, WSM

(5) Operator Presence Control (OPC) Switch

Top Cover and Grass Container Open Switch [GR1600EU,
GR1600F]
1. Remove the battery.
2. Remove the open switches (1) (2).
3. Measure the resistance with an ohmmeter between the switch
terminals.
4. If the switches are damaged, replace them.
Resistance
When plunger is pushed
(between switch
When plunger is released
terminals)
(1) Top cover Open Switch
OPC Switch (Seat Switch)
1. Remove the battery.
2. Remove the OPC switch (1).
3. Measure the resistance with an ohmmeter between the OPC
switch terminals.
4. If the OPC switch is damaged, replace it.
Resistance
When plunger is pushed
(between switch
When plunger is released
terminals)
(1) OPC Switch (Seat Switch)
6-S12
ELECTRICAL SYSTEM
0 Ω
Infinity
(2) Grass Container Open Switch
9Y1210595ELS0018US0
0 Ω
Infinity
9Y1210595ELS0019US0
KiSC issued 11, 2013 A