CHAPTER 16: PANEL MESSAGE
Warnings (requiring service calls)
Error Type
E01 [Replace battery]
E01-xxx
Description
!!Low Battery!!
Call Service
To reset
Press Reset Key, and replace the battery.
display
Error Point
Battery voltage was less than 2.1 V when the power was switched ON (weak battery: time to
010
replace battery).
Error Type
E02 [Maintenance call]
E02-xxx
Description
!!Maintenance!!
Call Service
To reset
Press Reset Key, and also reset the maintenance call value setting by test mode.
display
Error Point
Master counter reached the value set for the maintenance call (value set by test mode). [The
011
message appears when either the power is turned ON, the unit is reset, or when the machine
operation ended.]
Copy counter reached the value set for the maintenance call (value by set test mode). [The
012
message appears when either the power is turned ON, the unit is reset, or when the machine
operation ended.]
Maintenance counter inside the print drum reached the value set for the maintenance call
022
(value set by test mode). [The message appears when either the power is turned ON, the unit
is reset, or when the machine operation ended.]
RISO Inc. Technical Communications
Error Conditions
Error Conditions
[ 16 - 28 ]