P19 Thermal-Pressure Motor Lock; P20 Paper-Ejection-Section Motor Lock; P24 Inking Motor Lock - Riso RZ3xx Series Technical Manual

Table of Contents

Advertisement

Error Type
P19 [Thermal-pressure motor lock]
P19-xxx
!!System Error!!
Description
Press Reset Key
If Recovery has Failed, Call Service
To reset
Press Reset key
display
Error Point
TPH pressure sensor does not go OFF within 2 seconds after the thermal-pressure motor
207
activates in the decompressing direction, or during home positioning operation.
TPH pressure sensor does not go ON within 2 seconds after the thermal-pressure motor
208
activates in the decompressing direction.
TPH pressure sensor does not go OFF within 2 seconds after the thermal-pressure motor
216
activates in the compressing direction.
TPH pressure sensor does not go ON within 2 seconds after the thermal-pressure motor
217
activates in the compressing direction.
Error Type
P20 [Paper-ejection-section motor lock]
P20-xxx
!!System Error!!
Description
Press Reset Key
If Recovery has Failed, Call Service
To reset
Press Reset key
display
Error Point
416
Overload current was detected in the paper-ejection motor.
Paper-ejection FG sensor status does not change within 10 milliseconds after the paper-
437
ejection motor is activated.
Error Type
P24 [Inking motor lock]
P24-xxx
!!System Error!!
Description
Press Reset Key
If Recovery has Failed, Call Service
To reset
Press Reset key or turn the power OFF and ON.
display
Error Point
Inking-motor FG sensor status does not change within 20 milliseconds after the inking-motor
539
is activated.
RISO Inc. Technical Communications
Error Conditions
Error Conditions
Error Conditions
[ 16 - 11 ]
CHAPTER 16: PANEL MESSAGE
us.riso.com

Hide quick links: