CHAPTER 14: MASTER MAKING SECTION
11. Removing the Load Pulse Motor Assembly
(1) Pull out the master making unit and switch off the machine power.
(2) Open the master making unit upper cover and remove following items.
-
Master roll
-
master making cover front
-
Write pulse motor assembly
(3) Detach the reusable bands (3 locations) from the bracket of the load pulse motor and unplug the load
pulse motor connector.
(4) Remove screws (M3x6: 2pcs) and detach the load pulse motor assembly.
RISO Inc. Technical Communications
Reusable bands
Reusable band
[ 14 - 24 ]
Load pulse motor assembly
1447
us.riso.com