7. Removing the Master Disposal Box Safety SW
(1) Switch off the machine power and detach the master removal unit.
(2) Remove a screw (M3x6: 1pc) and detach the master disposal roller lock lever.
(3) Remove screws (M3x8: 3pcs) and detach the master disposal box guiding plate.
(4) Remove the switch spring.
(5) Disconnect the switch connector, remove a shoulder screw and detach the master disposal spring safety
SW together with switch bracket.
< View from
RISO Inc. Technical Communications
A
1028
Master disposal box guiding plate
Switch spring
A
>
1030
CHAPTER 10: MASTER REMOVAL SECTION
[ 10 - 13 ]
Master removal roller lock lever
Master disposal box safety SW
1029
1031
us.riso.com