Removing The Scanner Lamp - Riso RZ3xx Series Technical Manual

Table of Contents

Advertisement

CHAPTER 11: FB ORIGINAL SCANNING SECTION (600 dpi)

4. Removing the Scanner Lamp

(1) Run Test Mode No.287 (scanner lamp replace positioning) and switch off the machine power.
(2) Remove the stage glass.
(3) Remove screws( M3x6: 2pcs) and detach the inverter cover.
(4) Unhook the wire harness to the scanner lamp from the cord clamps (2 locations), and disconnect the
connector from the inverter.
(5) By lifting the clear plastic sheet on the cutout section of the scanner unit, remove screws (M3x6: 1pc
each) from the both sides, and detach the scanner lamp.
Cutout section
Connector
RISO Inc. Technical Communications
Scanner lamp
Cord clamps
Wire harness
Cutout section
1114
[ 11 - 10 ]
Inverter cover
Cutout section
1113
Scanner lamp
Clear plastic sheet
1115