Detailed List Of Panel Messages - Riso RZ3xx Series Technical Manual

Table of Contents

Advertisement

3. Detailed List of Panel Messages

Service call errors
Error Type
P01 [Main motor lock]
P01-xxx
!!System Error!!
Description
Press Reset Key
If Recovery has Failed, Call Service
To reset
Press Reset Key
display
Error Point
Main encoder sensor does not go ON/OFF within 10 milliseconds after the main motor
520
activates.
B-positioning sensor status does not change even after 3,033 pulses after the main motor
521
activates.
Clamp unit is not at the home position while the print drum is in operation (except during
524
master disposal).
537
Print drum failed to stop at position B. (over-run)
538
Print drum is not locked during operation. (Drum lock sensor: OFF)
Error Type
P02 [Elevator motor lock]
P02-xxx
!!System Error!!
Description
Press Reset Key
If Recovery has Failed, Call Service
To reset
Press Reset Key or turn OFF and ON the power.
display
Error Point
400
Both the upper and lower limit sensors are ON at the same time.
401
Overload current was detected in the elevator motor.
The lower-limit sensor does not go OFF within 2 seconds after the elevator motor operates in
404
the raising direction from the lower-limit position.
The upper-limit sensor does not go ON within 12 seconds after the elevator motor operates in
405
the raising direction.
The upper-limit sensor does not go OFF within 2 seconds after the elevator motor operates in
406
the lower direction from the upper-limit position.
The lower-limit sensor does not go ON within 12 seconds after the elevator motor operates in
407
the lowering direction.
The upper-limit sensor is OFF continuously for over 2 seconds during operation of the elevator
408
servo action to raise the feed tray.
RISO Inc. Technical Communications
Error Conditions
Error Conditions
[ 16 - 5 ]
CHAPTER 16: PANEL MESSAGE
us.riso.com