CHAPTER 9: CLAMP UNIT

Disassembly

1. Removing the Clamp Unit

(1) Switch off the machine power, remove the rear cover, and swing open the PCB bracket of the power
supply PCB and mechanical control PCB.
(2) Disconnect the clamp motor connector and relay connector. Remove screws (M4x8: 3pcs) and remove
the clamp unit from the machine.
Clamp motor connector
RISO Inc. Technical Communications
Clamp unit
< Clamp Unit >
[ 9 - 6 ]
Relay connector