2. Removing the Clamp Motor

(1) Switch off the machine power, remove the rear cover, and swing open the PCB bracket of the power
supply PCB and mechanical control PCB.
(2) Detach the clamp unit.
(3) Detach the helical/spur gear and spur gear by removing an E-ring on the helical/spur gear.
(4) Detach the clamp motor by unplugging the connector and removing the screws (M3x5: 2pcs).
Clamp motor
RISO Inc. Technical Communications
Connector
Helical / spur gear
[ 9 - 7 ]
CHAPTER 9: CLAMP UNIT
Spur gear