5. Removing the Master Removal Motor & Master Removal Motor FG sensor
Removing the master removal motor
(1) Switch off the machine power and detach the master removal unit.
(2) Remove an E-ring and detach the spur gear.
(3) Remove the timing belt.
(4) Disconnect the motor connector, remove screws (M3x5: 2pcs), and detach the master removal motor.
Removing the master removal motor FG sensor
(5) Disconnect the sensor connector and detach the master removal motor FG sensor.
Spur gear
Timing belt
RISO Inc. Technical Communications
CHAPTER 10: MASTER REMOVAL SECTION
1022
[ 10 - 11 ]
Master removal motor
Master removal motor FG sensor