login_prompt

This Annex parameter defines the prompt that appears for all ports using
a VMS interface. The string size ranges from 0 to 16 characters. The
default is the # symbol.
This parameter works only when cli_interface is set to vci.

login_timer

This Annex parameter specifies the number of minutes a port using a
VMS interface can remain inactive. Valid values are 0 through 60
(minutes). Entering 0 sets the timer to 30 minutes. The default is 30.
This parameter works only when cli_interface is set to vci.

login_timeout

This asynchronous port parameter enables a login timer when the VMS
command interface is configured (i.e., when cli_interface is set to
A Y enables this parameter, an N disables it. The default is N.
long _ break
This asynchronous port parameter enables an RA 6300 to return a user
to the CLI prompt after receiving a break signal of more than two seconds.
When disabled, the RA 6300 passes the break to the local application. A
Y enables this parameter, an N disables it. The default is Y.