The following example uses the admin command show port all to display
all asynchronous and TA global port parameters.
annex#: admin
admin: show port all
global port:
Port Generic Parameters
mode: cli
term_var: ""
cli_interface: uci
stop_bits: 1
max_session_count: 3
broadcast_direction: port
cli_imask7: Y
tcp_keepalive: 0
interactive
dedicated_arguments: ""
Flow Control and Signal Parameters
input_flow_control: eia
input_stop_char: ^S
output_start_char: ^Q
ixany_flow_control: N
v120_mru: 256
Port Timers and Counters
forwarding_timer: off
cli_inactivity: off
input_is_activity: Y
reset_idle_time_on: input
short_break: Y
Port Security Parameters
user_name: ""
connect_security: N
port_password: "<unset>"
ipx_security: N
(continued on next page)
Chapter 3
Configuring the PRI Interface, Global Ports,
location: ""
prompt: ""
data_bits: 8
parity: none
allow_broadcast: Y
imask_7bits: N
banner: Y
default_session_mode:
resolve_protocol: connect
input_start_char: ^Q
output_flow_control: eia
output_stop_char: ^S
need_dsr: N
forwarding_count: 0
inactivity_timer: off
output_is_activity: N
long_break: Y
autodetect_timeout: 30
cli_security: N
port_server_security: N
ipso_class: none