C-80
output _ flow _ control
This asynchronous port parameter defines the method that a device uses
to stop output from an RA 6300.
the default is start/stop.
Table C-26. Valid Options for the output_flow_control Parameter
Option
Description
bell
Comparable to setting the parameter to none.
eia
Selects hardware flow control; eia works only if the
control_lines parameter is set to flow control or both and the
device is wired properly.
start/
Specifies XON/XOFF flow control (independent of the
stop
control_lines parameter). Upon receiving XOFF
(output_stop_char), the RA 6300 stops sending output to the
device. Upon receiving XON (output_start_char), the RA 6300
starts sending output to the device. The RA 6300 removes these
characters from the data stream.
both
Specifies both in-band (XON/XOFF) and out-of-band
(CTS/RTS) flow control (if control_lines is set to flow_control
or both). Both flow controls are independent; data flows out of
the port only if CTS is high and the last received character was
XON. Receiving XOFF or dropping CTS stops output (RA 6300
to device) flow.
none
Specifies no flow control; characters are lost if the buffers
overflow.