Chapter 3
Configuring the PRI Interface, Global Ports, and Sessions
Remote Annex 6300 Supplement to the Remote Annex Administrator's Guide for UNIX
A-54
Table A-4. Parameters for the set pri Command (continued)
Parameter
num_b_channels
buildout
analog_encoding
Description
The maximum number of B channels that can be used
with the RA 6300. The default is 0, which the RA
6300 interprets as 23 for T1/PRI connections (in the
U.S.) and 30 for E1/PRI connections (in Europe and
Australia). Valid values are 1–23 for T1/PRI and 1–
30 for E1/PRI. The only time you might want to
change the default is in Europe, where telephone
company providers support PRI connections with
fewer than 30 channels (which can be cheaper).
(Applies only to RA 6300s with internal CSUs). A
string defining the CSU transceiver line provided by
the telephone company. Valid values are:
0db (the default)
7.5db
15db
22.5db
The encoding type used for modem calls. Valid
values are:
a_law (used for E1/PRI lines in Europe)
mu_law (used for T1/PRI in the U.S.)
auto (the default, which uses a_law or mu_law as
appropriate)
Typically, you do not need to change this parameter.
To check that the correct value is being used, issue
the pri command from the superuser CLI.