Chapter 15
Using RA 6300 Security
Remote Annex 6300 Supplement to the Remote Annex Administrator's Guide for UNIX
A-250
The information from acp_userinfo is loaded into the erpcd internal
database. To update the database, send a USR1 signal to erpcd (kill –
USR1 pid). When updating acp_userinfo, it is a good idea to check
syntax using the erpcd –u filename command (see erpcd on page C-115).
To create entries in the acp_userinfo file, use the following format, which
is referred to as a user...end block:
user username={name| profile_criteria}
entry
:
:
end
The syntax for profile_criteria is:
keyword=value [;keyword=value;...]
Entering profile criteria is described in detail in
on page 15-239.
If you use the name argument instead of profile_criteria, specify a valid
userid. This argument is supported for compatibility with Release 10.1
and earlier releases but is treated as if it were the profile criterion
username=name. In searching acp_userinfo, erpcd looks only for a first
match, whether that match is a single userid or all the criteria in a profile
criteria specification.