CDM-710/L Broadcast Satellite Modem
Serial Interface Operation
Controller-to-Target
Instruction Code & Qualifier
Parameter
Type
Command
Query
Faults and
Status
(continued)
Number of
Arguments for
Command or
(Note that all arguments are ASCII numeric codes from 48 and 57)
Response to
Query
8=Reserved
9=CDI-40 ASI Port Transmit FIFO Empty (Interface Slot 1)
A=Reserved
B=CDI-40 ASI Port Transmit FIFO Empty (Interface Slot 1)
C=Reserved
D= CDI-40 ASI Port Transmit Data Loss (Interface Slot 1)
E=Reserved
F= CDI-40 ASI Frame Not Synchronized (Interface Slot 1)
G=Reserved
H=CDI-60 HSSI Tx Clock Failure (Interface Slot 1)
I=Reserved
J=CDI-70 GBEI Module Datarate >+ 200 PPM (Interface Slot 2)
K= CDI-70 GBEI Module Datarate <- 200 PPM (Interface Slot 2)
L=CDI-70 GBEI No PHY Link
M=Encoder FIFO Empty
N=Encoder FIFO Full
O=CDI-40 ASI Tx Input Datarate Offset > +110PPM (Interface Slot 1)
P=Reserved
Q=CDI-40 ASI Tx Input Datarate Offset < -110PPM (Interface Slot 1)
R=Reserved
S=SERDES Parity Errors
c=Rx Traffic Status where:
0=No faults
1=+1.5V Demod Power Supply Unit (Demodulator Card)
2=FPGA Load (Demodulator Card)
3=Demod Unlocked
4=DSNG Sync Error
5=FPGA Temperature (Demodulator Card)
6=Reserved
7=AGC Level Out of Range
8=Eb/No Limit Exceeded
9=Demodulator Synth 1 PLL
A=Demodulator Synth 2 PLL
B= SERDES Demod to Framer
C= SERDES Framer to FEC1