Comtech EF Data CDM-710 Installation And Operation Manual page 242

70-140 mhz/l-band broadcast satellite modem
Table of Contents

Advertisement

CDM-710/L Broadcast Satellite Modem
Serial Interface Operation
Controller-to-Target
Instruction Code & Qualifier
Parameter
Type
Command
Query
Faults and
Status
(continued)
Firmware
N/A
FRW?i
Revisions
GBEI Egress
GEF=
GEF?
FEC Enable
Number of
Arguments for
Command or
(Note that all arguments are ASCII numeric codes from 48 and 57)
Response to
Query
R= Reserved
S= Reserved
T=HSSI Rx Buffer Underrun (Interface Slot 1)
U=HSSI Rx Buffer Overflow (Interface Slot 1)
V=Reserved
W=Reserved
X=Framer SERDES Rx Fault (Interface Slot 1)
Y=Framer SERDES Rx Fault (Interface Slot 2)
Z=Reserved
[=Reserved
d=New Faults where:
0=No new faults
1=New faults since last check
e=Configuration change where:
0=Unit configuration has not been changed
1=Unit configuration has been changed
2=Reserved
3=Gateway IP Address has been changed
NOTE: Typical for each parameter – Faults are listed in order of priority.
While multiple faults may exist, only the highest priority fault for that
parameter is returned.
1 byte
Query only.
Returns the firmware information of the system where:
i=Bulk Image number (1 or 2)
a=Firmware Image
b=Firmware Revision
c=Firmware Date
EXAMPLE: <0001/FRW?1{CR} (Queries the Bulk Image 1 firmware load)
2 bytes
Command or Query.
Sets or returns the CDI-70 GBEI Egress FEC operation in the form sn, where:
s=2 (Interface Slot 2 only)
n=Disable/enable, where 0=Disabled, 1=Enabled
9–34
Description of Arguments
MN/CDM710.IOM
Revision 12
Target-to-Controller
(See Description of Arguments)
Response to
Response to
Command
Query
FRW?
FRW={CR}Boot:{
FRW*
CR}a,b,c{CR}Bul
FRW#
ki:{CR}a,b,c{CR}
a,b,c...
GEF=
GEF=sn
GEF#
GEF?
GEF*

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdm-710l

Table of Contents