CDM-710/L Broadcast Satellite Modem
Rear Panel Connectors
Product
CDM-710
LDPC+BCH 32APSK 8/9
(70/140 MHz)
28 Msps S2-TS 120 MHz
CDM-710L
LDPC+BCH 32APSK 8/9
(L-Band)
28 Msps S2-TS 120 MHz
Item 2 – Press-fit Fuse Holder
Two 20mm Slo-blo type fuses are installed here for line and neutral fusing.
4.2.1.1 AC Operation – Replace the Fuses
As shown in Figure 4-5 (Item 2) and (Figure 4-6): The unit rear panel features a
fuse holder that is press-fit into the body of the IEC power module. The unit uses
two 20mm Slo-blo fuses – one each for line and neutral connections.
WARNING!
DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING!
CAUTION
FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES
WITH THE CORRECT TYPE AND RATING.
Do these steps to replace the AC fuses (Figure 4-6):
1. Unseat the fuse holder from the IEC power module.
a. Use the slot to pry the holder outward from the IEC power module.
b. Pull the holder straight out, and then swing the holder away from the
module.
Configuration
Voltage
120V AC
230V AC
120V AC
230V AC

Figure 4-6. Replace the AC Fuses

4–7
MN/CDM710.IOM
Revision 12
Frequency
Watts
Amps
60
83.5
0.738
50
83.0
0.503
60
87.2
0.770
50
86.5
0.579
VA
89
116
93
133