Front Panel Operation
7.2.1.4.2 (Config:) Int1 (Optional CDI-60 HSSI Data
Interface ONLY)
1) Due to limitations of the backplane, the CDM-710/L allows only
one data interface to be active. For example, if Interface 2 is
active, and you then enable Interface 1, the unit automatically
disables Interface 2.
2) The menu branch and submenus depicted in this section are
dependent on the presence of the optional CDI-60 HSSI Data
Interface Module, installable in Interface Slot 1 only.
There is a single port on the CDI-60 HSSI Data Interface. Use the   arrow keys
to select Tx, Rx, or CTS/RTS. Press ENTER.
(Config:) Intfc1 HSSI:  Tx
Use the   arrow keys to select Data, Clock, or Enable. Press ENTER.
(Config:) Intfc1 HSSI:  Tx  Data
Use the   arrow keys to select Datarate or Invert. Press ENTER.
(Config:) Intfc1 HSSI:  Tx  Data  Datarate
Intfc1 HSSI:
Tx Rx CTS/RTS
Intfc1 Tx
Data Clock Enable
Intfc1 Tx Data:
Datarate Invert
Intfc1 Data Rate:
Tx: 032.000000 Mbps
7–33
MN/CDM710.IOM
Revision 12
(E)