Table 4-2. 'P1 | Alarms' Connector Pinouts - Comtech EF Data CDM-710 Installation And Operation Manual

70-140 mhz/l-band broadcast satellite modem
Table of Contents

Advertisement

CDM-710/L Broadcast Satellite Modem
Rear Panel Connectors

Table 4-2. 'P1 | Alarms' Connector Pinouts

Pin #
8
Rx Traffic (De-energized, Faulted) (See notes)
15
Rx Traffic (Energized, No Fault)
7
Rx Traffic
14
Tx Traffic (De-energized, Faulted) (See notes)
6
Tx Traffic (Energized, No Fault)
13
Tx Traffic
5
Unit Fault (De-energized, Faulted) (See notes)
12
Unit Fault (Energized, No Fault)
4
Unit Fault
11
Rx I Channel (Constellation Monitor)
3
Rx Q Channel (Constellation Monitor)
10
No Connection
2
AGC Voltage (Rx signal level, 0-10 volts)
9
Ext Carrier Off (TTL Lo = Mute, Open = Tx)
1
Ground
1:N (CRS-300/710) and 1:1 Mode (CRS-170A, CRS-180)
Pin #
8
Summary Relay NC (De-energized, Faulted)
15
Summary Relay NO (Energized, No Fault)
7
Summary Relay COM (See notes)
14
Clock Detect
6
Aux Tx Enable
13
No Connection
5
Fused -12 VDC Output (160 mA max)
12
Fused +12 VDC Output (160 mA max)
4
Online
11
Serial Clock
3
Serial Data
10
Receive Serial Data – auxiliary channel
2
Transmit Serial Data – auxiliary channel
9
Ext Carrier Off (TTL Lo = Mute, Open = Tx)
1
Ground
1) The relays have low voltage contacts with transient suppressors
across each pin to ground. The Summary Relay combines Tx, Rx,
and Unit Faults into a single relay.
2) The maximum working voltage is 18VDC or 13V AC. The maximum
current rating is 1 Amp DC or 0.5 Amp AC.
Normal Mode
Description
Description
4–12
MN/CDM710.IOM
Revision 12
Name
Direction
Rx-NC
I/O
Rx-NO
I/O
Rx-COM
I/O
Tx-NC
I/O
Tx-NO
I/O
Tx-COM
I/O
Unit-NC
I/O
Unit-NO
I/O
Unit-Com
I/O
Rx-I
O
Rx-Q
O
NC
NC
AGC
O
EXT-OFF
I
GND
Gnd
Name
Direction
PR-NC
I/O
PR-NO
I/O
PR-COM
I/O
Clk Det
I
Red_Out_4
O
NC
NC
-12VDC
O
+12VDC
O
Red_In_2
I
Red_Out_1
O
Red_Out_2
O
Red_In_3
I
Red_Out_3
O
Red_In_1
I
GND
Gnd

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdm-710l

Table of Contents