12 Functional Descriptions
12.25.4 Memory configuration on control power-up
The user can now configure the NC memory according to his requirements by following the
procedure described below:
Select softkey "File functions" to call display 1:
Machine
Parameter
Start-up/Machine data/Standard data
Name
<online>
NCMEMCFG
Start-up/Machine data/Standard data
Name
Edit
Preset
Fig. 1
Select softkey "Preset" to copy file NCMEMCFG over into the user data area (file name
remains unchanged!).
By selecting softkey "Edit", you can now call the NCMEMCFG file in the user area in order to
edit it and to change the configuration values according to your requirements. Changes may
only be made in General reset mode. By selecting the edit function, you call displays 2, 3
and 4.
The MDD performs a plausibility check on the entered data. If a value which is lower/higher
than the minimum/maximum permissible limit is entered, the error message "Values only
from ... to ..." is output.