09.95
12.20.8
Configuration help for generator operation and emergency
retraction
12.20.8.1
Special case voltage failure
Requirements
The generator operation and emergency retraction functions on SINUMERIK 840C require the
following hardware and software:
•
Hardware components:
-
SINUMERIK 840C standard hardware
-
SIMODRIVE 611D standard hardware with modified drive control loops of the type
6SN1 118-0DG... or 6SN1 118-0DH...
-
Controlled infeed/regenerative feedback module (16 kW upwards) with suitable pulse
resistance module and possibly additional capacitors for the DC link.
-
Capacitor module (accessory 6FX2 006-1AA00: available as of the beginning of 1995)
to back up the power supply 115-230 V AC for the central unit and operator panel or
alternatively the 24 V DC power supply (available as of the 1st quarter of 1995) and
possibly 24 V DC operator panel (available as of 2nd quarter 1995).
•
Software components
-
System software SW 4.2
-
Generator operation option
-
Emergency retraction option (includes regenerative operation)
The following points must be noted for configuration:
1. The electronics of the drive controls must be powered from the DC link. With the
infeed/regenerative feedback modules, the connection with the DC link must be made (see
Start-up Guide 611).
2. NC and the operator panel must be backed up by suitable means, e.g.: capacitor module
for 230 V power supply or accumulator for 24 V power supply.
3. The supply to the PLC peripherals must be backed up by the accumulator.
DC link backup/total energy:
The energy available in the DC link of the drive units is calculated as follows in case of power
failure:
Zk 2
E
=
1/2 * C * (U
where
E
=
Energy in watt seconds [Ws]
C
=
Total capacity of the DC link in farads [F]
U
=
Content of the drive machine data 1634
Zk
U
=
Lower limit for safe operation taking the motor-specific emf into account, but
min
always above the switch-off threshold of 280 V
© Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
12.20.8 Configuration help for generator operation and emergency retraction
min 2
- U
)
6FC5197- AA50
12 Functional Descriptions
12–227