Kyocera KM-C2520 Service Manual page 69

Hide thumbs Also See for KM-C2520:
Table of Contents

Advertisement

Maintenance
item No.
Setting DP reading position modification operation
U087
Description
Sets the black line inspection at the time of reading the original from the DP.
Purpose
When using optional DP, to solve the problem when black lines occurs due to the dust with respect to original
reading position.
Method
1. Press the start key.
2. Select the item to be set. The screen for selecting an item is displayed.
Display
CCD
BLACK LINE
Setting: standard data when dust is detected
1. Change the value using the cursor up/down keys.
Display
CCD R
CCD G
CCD B
2. Press the start key. The value is set.
Setting: Initialization of original reading position
1. Select CLEAR.
2. Press the start key. The setting is cleared.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Outputting the MIP-PG pattern
U089
Description
Selects and outputs the MIP-PG pattern created by the machine.
Purpose
To check machine status other than scanner when adjusting image printing, using MIP-PG pattern output
(without scanning).
Method
1. Press the start key.
2. Select the MIP-PG pattern to be output.
Display
256GRADATION
COLOR BELT
GRAY
WHITE
GRADATION GRAY
3. Press the interrupt key.
When outputting gray PG of cyan/magenta/yellow, press Full-Color key and select the color on the Color
func.(Colour func.) screen.
4. Load the cassette with a sheet of A3 or 11" x 17" paper.
5. Press the start key. A MIP-PG pattern is output.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Setting of standard data when dust is detected.
Initialization of original reading position.
Description
Lowest density of the R regard as the dust.
Lowest density of the G regard as the dust.
Lowest density of the B regard as the dust.
Description
256-gradation PG
Four color belts PG
Gray PG
Blank paper PG
5-graduation gray PG
2FZ/2F0/2HC
Default
Setting range
setting
0 to 255
200
0 to 255
200
0 to 255
200
1-3-29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-c3225Km-c3232

Table of Contents