Kyocera KM-C2520 Service Manual page 113

Hide thumbs Also See for KM-C2520:
Table of Contents

Advertisement

Maintenance
item No.
U403
5. Change the setting value using the cursor up/down keys.
Increasing the value makes the margin wider, and decreasing it makes the margin narrower.
6. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following adjustments in
maintenance mode.
U403
Completion
Press the stop/clear key. The indication for selecting a maintenance item No. appears.
Adjusting margins for scanning an original from the DP
U404
Description
Adjusts margins for scanning the original from the DP.
Purpose
Make the adjustment if margins are incorrect when the optional DP is used.
Caution
Before making this adjustment, ensure that the following adjustments have been made in maintenance mode
U402
(P.1-3-71)
Adjustment
1. Press the start key.
2. Select the item.
Display
A MARGIN
B MARGIN
C MARGIN
D MARGIN
3. Press the interrupt key.
4. Place an original on the DP and press the start key to make a test copy.
Ejection direction
(reference)
Scanner
left margin
(2.0±1.0mm)
U404
(P.1-3-73)
U403
U404
(P.1-3-72)
Description
Left margin
Leading edge margin
Right margin
Trailing edge margin
Description
Scanner leading edge margin
(3.5±0.5mm)
Scanner trailing edge margin
(2.0±1.0mm)
Figure 1-3-20
Setting
range
0 to 10.0
0 to 10.0
0 to 10.0
0 to 10.0
2FZ/2F0/2HC-3
Scanner
right margin
(2.0±1.0mm)
Initial
Change in
setting
value per step
3.0
0.5 mm
2.5
0.5 mm
3.0
0.5 mm
4.0
0.5 mm
1-3-73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-c3225Km-c3232

Table of Contents