6. Remove the inserted parts and then remove
the MP forwarding pulley from the pulley
unit.
7. Remove two stop rings and bushes.
8. Remove the MP paper feed pulley from the
MP paper feed shaft.
Removing the MP separation pulley
9. Turn the MP unit over and remove the
spring.
10. Remove the separation pulley holder from
the MP unit.
11. Remove the inserted parts and then remove
the MP separation pulley from the separa-
tion pulley holder.
12. Clean or replace the MP forwarding, MP
paper feed and MP separation pulleys.
13. Refit the MP separation pulley to the sepa-
ration pulley holder.
14. Refit the MP forwarding and MP paper feed
pulleys to the pulley unit.
15. Refit the separation pulley holder and pulley
unit.
16. Refit the MP unit.
17. When the MP forwarding pulley, MP paper
feed pulley or the MP separation pulley is
replaced, perform maintenance mode U903
to clear the jam counter (see page 1-3-87).
1-5-8
MP paper feed shaft
Stop ring
Bush
MP paper feed pulley
MP unit
Separation pulley holder
MP forwarding pulley
Pulley unit
Figure 1-5-15
Spring
Separation pulley holder
Figure 1-5-16
MP separation pulley
Figure 1-5-17