2FZ/2F0/2HC
Maintenance
item No.
Setting the target
U425
Description
The value that is indicated on the back of the chart (P/N: 302FZ56990) to be used for adjustment should be
entered.
Purpose
Performs data input in order to correct for differences in originals during automatic adjustment.
Method
1. Press the start key.
2. Select the item to be set. The setting screen for the selected item is displayed.
Display
N8.75
N4.75
N1.25
CYAN
MAGENTA
YELLOW
RED
GREEN
BLUE
BLACK LINE
Setting: Lab value
1. Use cursor up/down keys to enter values shown on the back side of the test document
(P/N: 302FZ56990).
2. Press the start key. The value is set.
Setting: black stread distance value
1. Use cursor up/down keys to enter the distance value from edge A to the black streak on the test docu-
ment (P/N: 302FZ56990) in MAIN SCAN ADJ.
2. Use cursor up/down keys to enter the distance value from edge B to the black streak on the test docu-
ment (P/N: 302FZ56990) in SUB SCAN ADJ.
3. Press the start key. The value is set.
MAIN SCAN ADJ
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
1-3-76
Description
Description
Input the N8.75 Lab value
Input the N4.75 Lab value
Input the N1.25 Lab value
Input the cyan Lab value
Input the magenta Lab value
Input the yellow Lab value
Input the red Lab value
Input the green Lab value
Input the blue Lab value
Input black streak distance value of main scanning and auxiliary scanning
Figure 1-3-23
SUB SCAN ADJ