1615-Power Supply Failure, Power Supply Unplugged, or Power Supply Fan Failure
in Bay X
Audible Beeps: None
Possible Cause: The power supply has failed, or it is installed but not connected to the system board or AC
power source.
Action: Reseat the power supply firmly and check the power cable or replace power supply.
1616-Power Supply Configuration Failure
-A working power supply must be installed in Bay 1 for proper cooling.
-System Halted!
Audible Beeps: None
Possible Cause: Power supply is improperly configured.
Action: Run the server setup utility and correct the configuration.

1700 Series

1704-Unsupported Virtual Mode Disk Operation DOS Driver Required
Audible Beeps: None
Possible Cause: The operating system currently running does not support virtual DMA service.
Action: Load or update the SCSI device driver appropriate for the operating system.
1706-Smart Array Controller Extended BIOS Data Area Memory Corrupted.
...Int 13h BIOS Cannot Continue - System Halted.
Audible Beeps: None
Possible Cause: An application has overwritten memory reserved by the Smart Array controller.
Action: If this occurs when a particular application is loaded, check for an updated version of that
application.
1707 - Slot X Drive Array Controller - Bootstrap NVRAM checksum failed
The second line of the message includes one of the following lines of text:
(unrecoverable error)
or
(no suitable backup found)
Audible Beeps: None
Possible Cause: The Bootstrap NVRAM on the specified Smart Array controller is corrupt or invalid.
Action:
Update the controller with the latest firmware version.
1.
If the problem still exists, replace the controller.
2.
Error messages 140