Scsi Port X, Drive Id Y Was Replaced On A Good Volume: (Failure Message); Set Configuration Command Issued; Soft Firmware Upgrade Required; Storage Enclosure On Scsi Bus X Has A Cabling Error (Bus Disabled) - HP ProLiant series Troubleshooting Manual

Hide thumbs Also See for ProLiant series:
Table of Contents

Advertisement

Description: A predictive failure warning for this hard drive has been generated, indicating a drive
failure is imminent.
Action: Replace this drive at the earliest opportunity. Refer to the server documentation for drive
replacement information before performing this operation.

SCSI Port X, Drive ID Y Was Replaced On a Good Volume: (failure message)

Description: ADU
though no problem occurred with the volume.
Action: No action is required.

Set Configuration Command Issued

Description: The configuration of the array controller has been updated. The array accelerator board
may remain disabled until it is reinitialized.
Action: Run the server setup utility to reinitialize the array accelerator board.

Soft firmware upgrade required

Description: ADU
firmware that has been soft upgraded by the Upgrade Utility. However, the firmware running is not
present on all drives. This could be caused by the addition of new drives in the system.
Action: Update all drives to the latest firmware version.

Storage Enclosure on SCSI Bus X has a Cabling Error (Bus Disabled)...

...SOLUTION: The SCSI controller has an internal and external cable attached to the same bus. Please disconnect
the internal or external cable from the controller. If this controller supports multiple buses, the cable disconnected
can be reattached to an available bus.
Description: The current cabling configuration is not supported.
Action: Refer to the server documentation for cabling guidelines, and reconfigure as indicated.

Storage Enclosure on SCSI Bus X Indicated a Door Alert...

...SOLUTION: Be sure that the storage enclosure door is closed or the side panel is properly installed.
Description: The side panel of the external storage unit is open.
Action: Be sure the side panel of the storage unit is securely closed.

Storage Enclosure on SCSI Bus X Indicated a Power Supply Failure...

...SOLUTION: Replace the power supply.
Description: A power supply in the external storage unit has failed.
Action: Replace the power supply.

Storage Enclosure on SCSI Bus X Indicated an Overheated Condition...

...SOLUTION: Make sure all cooling fans are operating properly. Also be sure the operating environment of storage
enclosure is within temperature specifications.
("Array Diagnostic
Utility" on page 56) found that this drive was replaced, even
("Array Diagnostic
Utility" on page 56) has determined that the controller is running
Error messages 79