SC Error Codes
⇒
992 A Ink Collection Tank Full Error
At power on, the printer detected that the
left ink collection tank was full.
993 A High Voltage Leak
At power on or during a print job, a leak
detection signal was detected. The signal
was triggered by the accumulation of
condensation or ink spillage onto the
transport belt.
994 A Vertical Motor Error
The vertical encoder input signal was
judged to be abnormal when the vertical
motor was operating.
996 A No Input Signal from the Horizontal Encoder
No input signal from the horizontal
encoder was detected during operation of
the horizontal motor.
997 A Input Signal from the Horizontal Encoder Abnormal
When the carriage moved to the right, the
carriage did not stop at the HP. Or, the
carriage scan check failed.
999 A Maintenance Stepping Motor Out of Home Position
The maintenance motor HP sensor failed
to detect the motor at the home position.
J007/J010/J011
CÓPIA NÃO CONTROLADA
4-14
CÓPIA NÃO CONTROLADA
Rev. 02/2007
Replace the ink collection tank
with a new tank.
Never attempt to clean the old
tank and reinstall it.
Obey the local laws and
guidelines regarding disposal
of items such as the ink
collection tank.
This signal is triggered by the
HVPS due to an accumulation
of condensation or ink spillage
onto the transport belt.
Clean the transport belt.
Vertical encoder connector
loose, broken, or defective.
SENC defective.
Horizontal encoder sensor
loose, broken, or defective.
Horizontal encoder film
broken, disconnected, or
installed upside down.
HRB defective
Horizontal encoder sensor
loose, broken, or defective.
Horizontal encoder film
broken, disconnected, or
installed upside down.
HRB defective
Maintenance HP sensor
connector loose, broken, or
defective
Maintenance motor connector
loose, broken, or defective
SM