[25] Printer Gamma Sensor Adjustment

Use this function to make various adjustments concerning the gamma sensor.
Key Operator Mode Screen
Procedure
1 Touch

[25] Printer Gamma Sensor adjustment

Screen to display the Printer Gamma Sensor Adjustment Screen.
2 Select the desired adjustment item on the screen. Six items are provided: LS200,
LS150, DS200, DS150, CONTONE, and ED.
Touch
NEXT ADJUSTMENT
or previous adjustment item.
NOTE:
Some adjustment items cannot be displayed if the screen is specified as OFF
state in the Memory Switch setting.
Touching
Adj. data reset
to reset the adjustment value to the initial state, or touch
3 Touch
COPY SCREEN
Load several sheets of A4 paper on the Multi-sheet bypass tray, then press
[
START
] to output the test chart.
When output is completed, the Printer Gamma Sensor Adjustment Screen will
be restored, with the message "Please load output paper in Platen and push
[START] button" displayed.
4 Place the test chart face down on the platen glass with green arrow "*" pointing
at the left side as shown below, and put about 10 sheets of blank copy paper on
top of the chart.
Green arrow
[25] Printer Gamma Sensor Adjustment
Printer Gamma Sensor Adjustment Screen
or
PREVIOUS ADJUSTMENT
will display the Reset Confirmation Screen. Touch
to move to the Basic Screen to print a chart.
on the Key Operator Mode
to move to the next
NO
to cancel.
Place the chart
FACE DOWN
YES