3.

Power Save Mode

A press on the Save Power key on the control panel will lower the control temperature used
during STBY to reduce power consumption.
Power save mode
selected in user mode
Main heater
(H1)
Sub heater
(H2)
Controlled to 200˚C
200˚C
195˚C
180˚C
155˚C
110˚C
COPYRIGHT © 1999 CANON INC.
Save Power
key
ON
STBY
SLEEP
Temperature
control according
to saving rate
Saving by 10%
Saving by 25%
Saving by 50%
Figure 8-304 Sequence of Operations
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 8 FIXING SYSTEM
WMUPR omitted
Save Power
key
195˚C
200˚C
OFF
WMUP
The Save Power key is
turned off, returning to
normal temperature.
STBY
Controlled to 200˚C