CHAPTER 8 FIXING SYSTEM
C.

Controlling Temperature by Mode

The surface temperature of the fixing roller is controlled according to purpose for the following
operating modes:
Transparency mode
Thick paper mode
Power save mode
8-14
COPYRIGHT © 1999 CANON INC.
Purpose
To prevent wrapping of
transparencies.
To prevent drops in the surface
temperature of the fixing roller.
To reduce the power consumption.
Table 8-301
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Correction
Lowers the control temperature.
Increases the down sequence rush
temperature.
Lowers the control temperature for
STBY.