CHAPTER 8 FIXING SYSTEM
G.

Paper Sensors

1.

Removing the Claw Jam Sensor

1) Remove the fixing assembly from the
copier.
2) Remove the two screws, and detach the
lower separation claw assembly.
3) Detach the claw jam sensor [1] from the
right side of the lower delivery assembly.
2.
Removing the External Delivery
Roller
1) Remove the external delivery roller.
2) Remove the two screws [1], and detach
the external delivery sensor assembly [2].
3.
Removing the Internal Delivery
Sensor
1) Slide out the fixing assembly from the
copier.
2) Open the upper delivery assembly; then,
remove the two screws [1], and detach the
internal delivery sensor [2].
8-46
COPYRIGHT © 1999 CANON INC.
[1]
Figure 8-G501
[1]
Figure 8-G502
[1]
Figure 8-G503