4.

Removing the Reversal Sensor

1) Remove the fixing assembly from the
copier.
2) Open the upper delivery assembly; then,
remove the screw [1], and detach the re-
versal sensor [2].
5.
Removing the Fixing/Feeding Unit
Outlet Sensor
1) Remove the screw [1] from the bottom of
the fixing/feeding unit, and detach the fix-
ing/feeding outlet sensor [2].
COPYRIGHT © 1999 CANON INC.
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 8 FIXING SYSTEM
[2]
Figure 8-G504
[1]
Figure 8-G505
[1]
[2]
8-47