CHAPTER 11 INSTALLATION
No.
10
While keeping the lock released, push in
the primary charging assembly, and
connect the connector.
11
With the lock released, insert the
pre-transfer charging assembly, and
connect the connector.
Caution:
Check to make sure that the one-
way arm of the transfer charging
assembly is on top of the eccentric
cam.
12
Mount the primary charging assembly
cover and the pre-transfer charging
assembly cover with one screw each.
13
Close the front door.
11-12
COPYRIGHT © 1999 CANON INC.
Work
Eccentric cam