Adjusting The Nip - Canon GP605 Service Manual

Table of Contents

Advertisement

CHAPTER 8 FIXING SYSTEM
3.
Removing the Lower Fixing Roller
1) Remove the fixing assembly from the
copier.
2) Remove the fixing cleaning belt; then,
clean and detach the oil pan.
3) Open the upper fixing unit.
4) Remove the two screws [1], and detach
the lower separation claw support plate
[2].
5) Remove the lower roller [3] from the fix-
ing assembly, and remove the E-rings [4]
and the bearings [5] from both front and
rear.
4.

Adjusting the Nip

a.
Measuring the Nip
Be sure to wait 15 min or more after the
copier finishes warm-up; then, make 20
A4 copies, and perform the following:
1) Place A3 paper, and select A3 on the con-
trol panel.
8-40
COPYRIGHT © 1999 CANON INC.
[1]
[2]
Figure 8-D510
[3]
Figure 8-D511
CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
[1]
[4]
[5]